Device description
Function
The plasma generator is a part of an atmospheric pressure plasma generator used for atmospheric plasma treatment or pretreatment of a very wide variety of material surfaces.
It is designed for industrial applications where, for example, surfaces are activated with plasma and cleaned prior to printing, bonding or painting. The application of surface coatings is also possible.
The device is also suitable for laboratory operation by instructed personnel.
Device overview:
No. Component
1 Plasma generator
3 Plasma electrode (inner electrode)
Note:Plasma nozzle (outer electrode) – not included – (shape may vary depending on application)
Spare parts
No. Component
1 Plasma generator
2 Ceramic spacer sleeve
3 Ceramic sleeve
4 Nut
Technical data
Designation
|
|
Value
|
|
|
|
Working voltage of plasma
|
|
• up to 20 kV (max. voltage during ignition)
|
generator
|
|
• up to 2 kV (average operating voltage)
|
|
|
|
|
|
|
Dimensions
|
|
|
|
|
|
|
•
|
Plasma generator
|
|
Mass: 0.5 kg; 1.1 lbs depending on configuration
|
|
|
|
Cable length: 1.000 mm (39.4“) or 2.000 mm (78.7“) depending on configuration
|
|
|
|
|
|
|
|
Ø Clamping area Plasmagenerator: 32mm; 1.26“
|
|
|
|
Ømax HV-Plug: 22mm; 0.87
|
|
|
|
|
•
|
Minimum bending
|
|
120 mm; 4.72"
|
|
radius of HV cable
|
|
|
|
|
|
|
•
|
Maximum torsion cable
|
|
±180°/2m
|
|
extension
|
|
|
|
|
|
Limit temperature
|
|
|
|
|
|
|
•
|
Plasma generator
|
|
≤ 200 °C; 392 °F
|
|
|
|
Operating conditions
|
|
|
|
|
|
|
•
|
Air humidity
|
|
< 80% rel. (non-condensing)
|
|
|
|
|
•
|
Temperature
|
|
10 – 40 °C; 50 – 104 °F
|
|
|
|
Storage conditions
|
|
|
|
|
|
|
•
|
Air humidity
|
|
< 80% rel. (non-condensing)
|
|
|
|
|
•
|
Temperature
|
|
0 – 60 °C; 32 – 140 °F
|
|
|
|
Noise emission
|
|
|
|
|
|
• Sound pressure level at
|
|
> 85 dB(A) with a gas flow > 40 Nlm
|
|
distance of 1 meter
|
|
|
|
|
|
Gas connection
|
|
|
|
|
|
|
•
|
Gas types
|
|
Compressed air (purified, free of oil and lubricants)
|
|
|
|
Nitrogen (tech. gas, free of particles and oil)
|
|
|
|
Other types only by agreement with relyon plasma.
|
•
|
Gas flow
|
|
35 – 80 Nlm
|
|
|
|
|
•
|
Quality
|
|
Compressed air 1.4.1 according to ISO 8573.1
|
|
|
|
Nitrogen 2.8 (N2) according to DIN EN ISO 14175:N1
|
|
|
|
|
•
|
Connection
|
|
6 mm quick-action coupling
|
|
|
|
|
|