plasma power supply
Description of machine
Function
The Plasma power supply forms part of an atmospheric-pressure plasma generator for the atmospheric plasma treatment or pretreatment of a wide range of surfaces.
It is intended for industrial applications where surfaces are activated or cleaned with plasma prior to printing, gluing or painting. It may also be used for surface-coating.
The housing is intended for installation in a control cabinet.
Scope of delivery
The scope of delivery includes the following components:
• Plasma power supply.
• Power connector for the electrical supply voltage connection, comprising sleeve support, socket insert and cable screw connection (Harting HAN 3).
• Round plug connector for connecting and integrating the PS2000 in internal or external
emergency stop circuit (Harting HAN M12).
• Operating instructions.
Technical data
Description Value
|
data
|
Electrical data
|
Electrical connection
|
220V – 240V AC / 50-60Hz / max. 6A
|
Mains fuse
|
F1 = 6.3 A, time lag fuse, 230 V
|
Power consumption
|
≤ 1200 VA
|
Power loss Pmax:
|
Pmax: 450 W
|
Protection
|
IP 20 acc. to EN 60529
|
Protection class Class
|
Class I acc. to IEC 61140
|
Operating voltage of plasma generator
|
• up to 20 kV Upeak (max. voltage for ignition (briefly))
|
• up to 2 kV RMS (average operating voltage)
|
Internal F1, F2 fuses
|
6.3A / 500VAC /time lag, SIBA type 189140.6.3
|
Mass
|
Weight
|
18.0 kg; 39.7 lbs
|
Dimensions
|
483 x 177 x 430 mm (equals 4 HU);
19" x 6.97" x 16.93" (WxHxD)
|
Operating conditions
|
Air humidity
|
< 80% rel. (non-condensing)
|
Temperature
|
0-40°,32-104°F
|
Storage conditions
|
Air humidity
|
< 80% rel. (non-condensing)
|
Temperature
|
0-60°,32-104°F
|
Noise emissions
|
• Sound level
|
< 60 dB(A) at 1 meter away
|
|